Overview

Gets parameters in other modules

Discussion

The ParamGet module gets the value of a parameter from another module.

At instantiation time (or in Module Name and Arguments in Audio Weaver Designer), you specify the data type of the input pin and also the variable which will be fetched. The variable is specified as

Mod.Var

where Mod is the name of the module (in the same level of the hierarchy as the ParamGet module) and Var is the variable name. You can also specify modules that are within subsystems using

Subsystem.Mod.Var.

You can also go up in hierarchy and get parameters from modules that are in an upper system. Use a single backslash character to move up one level in the hierarchy. Use multiple backslash characters to traverse multiple levels of hierarchy. Suppose that the ParamGet module is located in:

SYS.Subsystem.ParamGet

and you want to get the variable

SYS.Scaler1.gain

Then set the Mod.Var field to

\Scaler1.gain

And finally, you can also get individual values from arrays using the syntax

Mod.Var[index]

where index is the zero-based index of the element in the array Var to get.

Please see the ParamGet example for specific use cases.

Type Definition

typedef struct _ModuleParamGet { ModuleInstanceDescriptor instance; // Common Audio Weaver module instance structure void * modPtr; // Points to the module to get void * varPtr; // Points to the variable to get within the module instance structure } ModuleParamGetClass;

Variables

Properties

Name

Type

Usage

isHidden

Default value

Range

Units

modPtr

void *

parameter

1

 

Unrestricted

 

varPtr

void *

parameter

1

 

Unrestricted

 

Pins

Output Pins

Name: out

Description: parameter value

Data type: float

MATLAB Usage

File Name: param_get_module.m

M=param_get_module(NAME, DATATYPE, MODVAR) Parameter get module. This module can reach into the instance structure of other modules and gets the parameter values. Arguments: NAME - name of the module. DATATYPE - string specifying the data type of the variable and also used for the data type of the input pin. Allowable values are 'float', 'int', or 'fract32'. Implicit casts from 'int' to 'uint' variables allowed, but take caution to avoid passing out of range values. MODVAR - specifies the module and variable name using the form: 'MOD.VAR' where MOD is the module name and VAR is the variable name. You can also specify internal subsystems using 'SUBSYS.MOD.VAR'. EXECUTIONORDER - Determines when the ParamSet module executes relative to the module it is controlling. Allowable values are: 'undefined' - the default. The execution order is set by the routing algorithm and can occur before or after the module it is controlling. 'before' - forces ParamSet to execute before the module it is controlling. 'after' - forces ParamSet to execute after the module it is controlling. When using 'before' and 'after' you could get a build error indicating that no more modules can execute or there is a circular dependency.