Danville_Source_Select
Overview
Source Select Control
Discussion
This module allows users to select an input signal source. Please refer to the accompanying documentation of the target hardware Note that if user selects an unsupported value, target will use default value instead. The default value field gives users to enter a one time initialization value for this module instance. Clicking the overrride checkbox allows user to use a value entered via inspector.
Type Definition
typedef struct _ModuleDanville_Source_Select
{
ModuleInstanceDescriptor instance; // Common Audio Weaver module instance structure
INT32 Source_Select_Val; // Source Select Value
INT32 Source_Select_Default_Val; // Source Select Default Value
INT32 Source_Select_OLD_Val; // Source Select OLD Value
INT32 Source_Select_Override; // Source Select Override
} ModuleDanville_Source_SelectClass;
Variables
Properties
Name | Type | Usage | isHidden | Default value | Range | Units |
Source_Select_Val | int | parameter | 0 | 0 | 0:31 | Â |
Source_Select_Default_Val | int | parameter | 0 | 0 | 0:31 | Â |
Source_Select_OLD_Val | int | parameter | 0 | 0 | 0:31 | Â |
Source_Select_Override | int | parameter | 0 | 0 | 0:1 | Â |
Pins
Output Pins
Name: out
Description: Source Select
Data type: int
MATLAB Usage
File Name: Danville_Source_Select.m
M=Danville_Source_Select_module(NAME)
Copyright 2016. Danville Signal Processing, Inc. All Rights Reserved.
Author: E. Enrique
$Revision: 1.1 $
Â