Overview

Block statistics of a block of samples

Discussion

This module calculates the Block Statistics of the input signal on a block-by-block basis. The input pin can have an arbitrary number of interleaved channels and the Block Statistics calculation occurs over all channels. The output pin has a single channel and a blockSize of 1.

statisticsType

Description

0

maximum

1

minimum

2

maximum absolute value

3

mean

4

RMS

5

standard deviation

6

variance

7

average energy

8

sum

9

sum of squares

The module also exposes computed signal as state variable; instantaneousValue holds the Block Statistics of the block.

Type Definition

typedef struct _ModuleBlockStatisticsFract32
{
    ModuleInstanceDescriptor instance;            // Common Audio Weaver module instance structure
    INT32 statisticsType;                         // Type of statistics needed
    fract32 instantaneousValue;                   // Instantaneous output value
} ModuleBlockStatisticsFract32Class;

Variables

Properties

Name

Type

Usage

isHidden

Default value

Range

Units

statisticsType

int

parameter

0

0

0:7

instantaneousValue

fract32

state

0

0

-60:10

Pins

Input Pins

Name: in

Description: Audio input

Data type: fract32

Channel range: Unrestricted

Block size range: Unrestricted

Sample rate range: Unrestricted

Complex support: Real

Output Pins

Name: out

Description: Block statistics output

Data type: fract32

MATLAB Usage

File Name: block_statistics_fract32_module.m

 M=block_statistics_fract32_module(NAME, OUTPUTVALUE)
 This modules calculates statistics of the input signal on a block-by-
 block basis.  A number of different statistics can be calculated based
 on the statisticsType parameter.  The computed value is stored in the
 internal state variable instantaneousValue.  Arguments:
    NAME - name of the module.
    OUTPUTVALUE - Boolean  value which specifies whether the module has
                  an output pin.  If OUTPUTVALUE=0, then the module has no
                  output pin.  If OUTPUTVALUE=1 (the default), then
                  the instantaneousValue variable is output as a single
                  sample on the output pin.
 The argument statisticsType determines what statistics computed:
   0 = maximum
   1 = minimum
   2 = maximum absolute value
   3 = mean
   4 = RMS
   5 = standard deviation
   6 = variance
   7 = average energy