The ClockDivider field in Properties when left blank will default to 1A0. This represents clock divider “1”, Thread (subLayoutID) “A” and instance “0”. The instance value can be changed to move that module to a designated core (4 virtual cores by default in Designer [0,3]) and profiled separately. The clock divider changes as a result of buffering up or down.

(Multi Instance only): The instanceID of an AWE command is determined by the instanceID of a module/wire in the design. The instanceID is a propagatable field, and can be modified using the 'ChangeThread' module, or, for a source module, by setting the clockDivider field in the build tab of the module properties. The syntax to set the clockDivider field is <clockDivider (#)><threadThead (letter)><instanceID (#)>, so '2B3' will run the source module with clockDivider of 2, on thread B of instance 3. The 'ChangeThread' module exists to take one or more input wires of data that exists on one instanceId, and send it to another user-specified instanceId.

Note: The clock divider field is only user editable for source modules and automatically assigned for the rest.

...