This modules provides a flexible level meter that can operate in several modules. The module has a single multichannel input and separately meters each channel. The meter can be configured to conform to IEC 60280-10 (peak meters) and IEC 60280-17 (VU Meter) specifications. The meterType parameter is used to configure the module as follows.

...

meterType

Description

Attack Time (msec)

Release Time (msec)

Comments

0

FastPeakSample

5

1087

Peak meter: IEC 60280-10

...

"fast mode"

...

...

1

...

SlowPeakSample

10

1450

Peak meter: IEC 60280-10

...

"slow mode"

...

...

2

...

VUMeterSample

65

65

IEC 60280-17

...

standard "VU meter"

...

...

3

...

CustomSample

user

user

Set the attackTime and releaseTime from a Matlab script

...

...

4

InstantSample

0

0

Instantaneous (attack and release times of 0 msec). The meter value equals the last value in each block.

...

16

...

FastPeakBlock

5

1087

Computationally efficient peak meter: IEC 60280-10

...

"fast mode"

...

...

17

...

SlowPeakBlock

10

1450

Computationally efficient peak meter: IEC 60280-10

...

"slow mode"

...

...

18

...

VUMeterBlock

65

65

Computationally efficient IEC 60280-17

...

standard "VU meter"

...

...

19

...

CustomBlock

user

user

Computationally efficient custom meter. Set the attackTime and releaseTime from a Matlab script

...

...

20

...

InstantBlock

0

0

Computationally efficient instantaneous (attack and release times of 0 msec). The max abs value of each block is returned

...

without time constants.

In meterTypes 0 to 4, the peak attack and release are performed on a sample-by-sample basis in the envelope follower. In meterTypes 16 to 20, the peak absolute value for the entire input block is found and this one value is passed through the envelope follower.

Type Definition

Code Block
typedef struct _ModuleMeter
{
    ModuleInstanceDescriptor instance;            // Common Audio Weaver module instance structure
    INT32 meterType;                              // Operating mode of the meter. Selects between peak and RMS calculations. See the discussion section for more details.
    FLOAT32 attackTime;                           // Attack time of the meter. Specifies how quickly the meter value rises.
    FLOAT32 releaseTime;                          // Release time of the meter. Specifies how quickly the meter decays.
    FLOAT32 attackCoeff;                          // Internal coefficient that realizes the attack time.
    FLOAT32 releaseCoeff;                         // Internal coefficient that realizes the release time.
    FLOAT32* value;                               // Array of meter output values, one per channel.
} ModuleMeterClass;

...