Overview
Peak and RMS meter module
Discussion
This modules provides a flexible level meter that can operate in several modules. The module has a single multichannel input and separately meters each channel. The meter can be configured to conform to IEC 60280-10 (peak meters) and IEC 60280-17 (VU Meter) specifications. The meterType parameter is used to configure the module as follows.
...
In meterTypes 0 to 4, the peak attack and release are performed on a sample-by-sample basis in the envelope follower. In meterTypes 16 to 20, the peak absolute value for the entire input block is found and this one value is passed through the envelope follower.
Type Definition
Code Block |
---|
typedef struct _ModuleMeter { ModuleInstanceDescriptor instance; // Common Audio Weaver module instance structure INT32 meterType; // Operating mode of the meter. Selects between peak and RMS calculations. See the discussion section for more details. FLOAT32 attackTime; // Attack time of the meter. Specifies how quickly the meter value rises. FLOAT32 releaseTime; // Release time of the meter. Specifies how quickly the meter decays. FLOAT32 attackCoeff; // Internal coefficient that realizes the attack time. FLOAT32 releaseCoeff; // Internal coefficient that realizes the release time. FLOAT32* value; // Array of meter output values, one per channel. } ModuleMeterClass; |
Variables
Properties
Name | Type | Usage | isHidden | Default value | Range | Units |
meterType | int | parameter | 0 | 18 | Unrestricted | |
attackTime | float | derived | 1 | 65 | 0:1000 | msec |
releaseTime | float | derived | 1 | 65 | 0:10000 | msec |
attackCoeff | float | derived | 1 | 0.02336 | Unrestricted | |
releaseCoeff | float | derived | 1 | 0.02336 | Unrestricted | |
value | float* | state | 0 | [1 x 1] | -60:10 | linear |
Pins
Input Pins
Name: in
Description: audio input
...
Sample rate range: Unrestricted
Complex support: Real
Scratch Pins
Channel count: 1
Block size: 32
Sample rate: 48000
MATLAB Usage
File Name: meter_module.m
...